RADEAGLET Ruggedized

Key product features in a nutshell

RADEAGLET Ruggedized, in short the RTR, is a robust and ruggedized is a special version of the RADEAGLET. It specifically addresses the challenges of in-field missions and contributes to combatting nuclear terrorism.

You can also directly jump to the Technical Specification, or download our product brochure right below... 


 
GPS and GLONASS

Spectroscopic and radiologic data measured with RADEAGLE is tagged with geographical information, once the optional GPS module is installed. 


Powerful algorithm for nuclide identification

The identification of nuclides is based on the spectrum. On the computer system of RADEAGLET runs a powerful mathematical algorithm that identifies radioactive sources based on this spectrum. It can also find the right composition, if multiple of these sources are there simultaneously.

 

Describing the engine behind it would be lengthy. If you are affine to keywords: a multi-agent system with an armada of over 100 functional agents, a stochastic deconvolution and a self-learning Kalman filter are vital components in its realization. Sometimes, we call it a neuro-spectroscopic brain.

 
Long-lasting battery power
A smart lithium power unit with digital lifetime processing. Users can check visually the battery status via the inbuilt indicator display. 
 

Always calibrated in the era of machine learning

RADEAGLE does not use any internal source. It does not contain any radiating material at all! Instead, we use the natural background radiation. See the tiny little peak in the spectrum? This is a peak of 40K. It is nearly always there. This is one of many peaks RADEAGLE grabs to keep the calibration in place. And because our detector is so large, it sees the tiny peak very quickly.

The software also applies machine learning techniques for storing the complicated dependencies of the peak position and the temperature.  Each individual instrument is virtually "trained" at innoRIIDs European production facilities, not only with respect to temperature values but especially to different temperature change rates (shocks). 

 

If you require a unit with internal source, we can optionally equip the RADEAGLE with a small 137Cs source. 


Technical Specifications Common to All Models

Radiological Performance
Energy Range/MCA 11 keV to 3 MeV / 2048 channels
Calibration Source

Natural background. No internal source required. 

Optional: 137Cs source

Nuclide Library

Default Isotopes:
 241Am, Beta+, 133Ba, 207Bi, 109Cd, 252Cf (requires neutron detection), 57Co, 60Co,

51Cr, 134Cs, 137Cs, 152Eu, 67Ga, 68Ga, 123I, 125I, 131I, 111In, 192Ir,  40K, 54Mn, 99Mo,

22Na, 237Np, 226Ra, 75Se, 90Sr,  99mTc, 232Th, 201Tl, 131mXe, 133Xe, 133mXe, 135Xe, 

176Lu, 95Zr, 125Sb, 132Te, 95Nb, 132I, 228Ac, 140Ba, 155Eu, 147Nd, 115Cd, 115mCd,  

103Ru, 144Pr, 140La, 141Ce, 75Se

 

Uranium: 233U, 235U and 238U in different enrichment ratios, including depleted uranium 

Plutonium: 238Pu, 239Pu in reactor-grade and weapon grade compositions including 240Pu, 241Pu

 

Nuclide Categories

Special nuclear material (SNM)

Naturally occurring radiation (NORM)

Industrial emitter (IND)

Medical source (MED)


Physical
Dimensions 248 mm x 115 mm x 152 mm (9.8” x 4.5” x 6.0”)
Display 640 x 480, 89 mm (3.5”) Transflective Color TFT
Batteries Rechargeable AA NiMH battery pack, auxiliary battery case for AA NiMH or alkaline
Operational Run Time >16 hours with standard battery pack

Environmental
Operating Temperature –20 °C to +50 °C (–4 °F to +122 °F )
Relative Humidity 10% – 90%, non-condensing
Protection Rating IP65, submersible to 15 meter for models 3SGA and 3SGA-H

Computational
Memory >16 GB (1,000,000 spectra)
CPU Speed 1 GHz
File Formats ANSI N42.42, SPE (IAEA)
Connectivity USB, WiFi, GPS (optional)

Software
Operating System Microsoft Windows (XP, Vista, 7, 8, 10), MAC OS X Yosemite, Linux (tested for Ubuntu)

1Refers to the NaI(Tl) variant of the instrument. Other detector options feature different geometries.